Products

Featured products

  • All SS Vibration Absorber For Ammonia
    All SS Vibration Absorber For Ammonia
    Our Vibration Absorber is produced with deep pitch stainless steel corrugated tube and high tensile wire braid, Each end is TIG welded by stainless steel ferrules and clamped the wire braid by high pressure clamping machine. A stopper can also be designed on each connection end, providing a more positive seal and low leak rate. All Vibration Absorbers are tested twice by Helium and hydraulic leak test machine. OEM designed Vibration Absorber is also available. Max working pressure is from 44.8 bar to 13 bar, working temperature is from -40℃ to +120℃ . UL and CE certified.
    More
  • Korea High Pressure Vibration Absorber
    Korea High Pressure Vibration Absorber
    1. The core of the Honway refrigeration system vibration absorber features a deep-corrugated stainless steel tube encased in a high-strength stainless steel wire mesh, capable of withstanding working pressures of up to 44.8 bar. 2. Leveraging our in-house automated manufacturing facilities, every Honway vibration absorber undergoes a rigorous closed-loop quality control process, utilizing technologies such as fully automated helium leak detection and automated TIG welding. 3. Established in 2010, the company employs 50 technical experts and has accumulated experience from thousands of industry projects; our products boast a 98% satisfaction rate.
    More
  • High Quality Vibration Absorber For Refrigeration Equipment
    High Quality Vibration Absorber For Refrigeration Equipment
    1. The Refrigeration vibration eliminator is designed to withstand the harsh operating pressures of the R410A system, with a maximum operating pressure of 13 bar to 44.8 bar and an operating temperature range of -40°C to +120°C. 2. The Refrigeration vibration eliminator features TIG welding at both ends and is constructed entirely of deep-pitch stainless steel bellows and high-strength steel wire braid, significantly enhancing its durability.
    More
  • R410A High Pressure Vibration Absorber
    R410A High Pressure Vibration Absorber
    1. Our R410A Vibration Absorber is produced with deep pitch stainless steel corrugated tube and high tensile wire braid, Each end is TIG welded by stainless steel ferrules and clamped the wire braid by high pressure clamping machine. 2. A stopper can also be designed on each connection end, providing a more positive seal and low leak rate. All Stainless vibration absorbers are tested twice by Helium and hydraulic leak test machine. 3. OEM designed High pressure vibration absorber is also available. Max working pressure is from 44.8 bar to 13 bar, working temperature is from -40℃ to +120℃ . UL and CE certified.
    More

Contact us

  • High Quality Flexible Hose For Refrigeration Equipment
  • High Quality Flexible Hose For Refrigeration Equipment
  • High Quality Flexible Hose For Refrigeration Equipment
  • video

High Quality Flexible Hose For Refrigeration Equipment

Our Flexible Hose is produced with deep pitch stainless steel corrugated tube and high tensile wire braid, Each end is TIG welded by stainless steel ferrules and clamped the wire braid by high pressure clamping machine. A stopper can also be designed on each connection end, providing a more positive seal and low leak rate. All Flexible Hoses are tested twice by Helium and hydraulic leak test machine. OEM designed Flexible Hose is also available. Max working pressure is from 44.8 bar to 13 bar, working temperature is from -40℃ to +120℃ . UL and CE certified.
  • COOLMATE, HONWAY
  • CHINA
  • 2-4 weeks
  • 1000 pcs/day

Introduction for High Quality Flexible Hose for Refrigeration Equipment



High Quality Flexible Hose

Flexible Hoses are installed in the suction and discharge lines of Air conditioning and Refrigeration system to eliminate vibration and noise which compressor generates, and for reducing stress linked with piping thermal expansion in AC&R.


Each Flexible Hose is 100% pressure tested by helium leak detector and hydraulic leak tester. All units are carefully cleaned, dehydrated and sealed in film and packed into individual box after final inspection.


Flexible Hoses are compatible with all kinds of refrigerants and lubricants.


Product features



* Deep pitch stainless steel corrugated tube and high tensile wire braid, Each end is TIG welded by stainless steel ferrules and clamped the wire braid by high pressure clamping machine.

* A stopper can also be designed on each connection end, providing a more positive seal and low leak rate. 

* All Flexible Hoses are tested twice by Helium and hydraulic leak test machine.

* OEM designed Flexible Hose is also available. 

* Max working pressure is from 44.8 bar to 13 bar, working temperature is from -40℃ to +120℃ . 

* UL and CE certified.


Specifications



Flexible Hose for Refrigeration Equipment




Model    MWP
    barg(psig)
Max.   working    Temperature
    ℃
Min.   working    Temperature
    ℃
UL rated   burst
    pressure
    barg (pisg)
HES-014 44.8 (650)+120 -40224.0 (3250)
HES-03844.8 (650)+120 -40224.0 (3250)
HES-01244.8 (650)+120 -40224.0 (3250)
HES-05844.8 (650)+120 -40224.0 (3250)
HES-03444.8 (650)+120 -40224.0 (3250)
HES-07844.8 (650)+120 -40224.0 (3250)
HES-11841.3 (600)+120 -40206.8 (3000)
HES-13837.9 (550)+120 -40189.6 (2750)
HES-15835.1 (510)+120 -40175.8 (2550)
HES-21827.5 (400)+120 -40137.8 (2000)
HES-25824.1 (350)+120 -40120.6 (1750)
HES-31822.0 (320)+120 -40110.3 (1600)
HES-35813.0 (190)+120 -4039.3 (570)
HES-41813.0 (190)+120 -4039.3 (570)


Product details



High Quality Flexible Hose



  • How To Choose The Perfect Mini Split Line Set?

    In a mini-split system, line sets function the same, except instead of carrying oxygen and nutrients, they transport refrigerant that brings the heat into or out of our homes. Unless selected and installed properly, your air conditioning, heat pump, and mini split system will not work as designed. Must-Have Accessories The first one is called Rectorseal NoKink and is a flexible refrigerant line connector just for mini-split systems. It connects the line set to the evaporator head unit and eliminates the worry of kinking the lines, hence the "NoKink" name. It's also can be found in our product list named "Mini-Split line set connectors"
  • What's The Difference Between R-22 And R-410a?

    One of the hottest discussions within the air conditioning and heating industry is the difference between two refrigerants: R-22 and R-410A. We've outlined below the main differences and why they matter. R-22 * Often referred to by a brand name like Freon * As of 2010, R-22 was discontinued for use in new air conditioning systems * R-22 is a hydro-chlorofluorocarbon (HCFC) which contributes to ozone depletion * Does not absorb as much heat. meaning there is a higher risk for AC compressor burnout due to overheating R-410A * Often referred to by a brand name like Puron * Has been approved for use in new residential air conditioners * Is a hydro-fluorocarbon(HFC) which does not contribute to ozone depletion * Will become the new standard for U.S. residential air conditioning systems in 2015 * Absorbs and releases more heat so your AC compressor can run cooler,reducing the risk of compressor burnout R-410A also functions at a higher pressure than R-22, so new compressors are built to withstand greater stresses, reducing the chance for cracking. If you were to put R-410A refrigerant into a system designed for R-22, the pressure would be too much and the unit would break. All air conditioners use an oil to keep the compressor lubricated during operation. R-22 air conditioners use mineral oil and R-410A systems use synthetic oil. The synthetic oil is generally more soluble with R-410A than mineral oil is with R-22. This means the R-410A system operates more efficiently reducing wear and tear on the compressor.
  • Can Our Vibration Absorber Be Used for Ammonia Refrigeration System?

    Pressure piping of Ammonia refrigeration system operates in a specific environment and specific parameters. And safety performance of pressure piping is related to design, installation, inspection and testing and use. Our All stainless steel Vibration Absorber can be used for Ammonia Refrigeration System. The working pressure can be up to 60 bar.
  • Is Customized Vibration Absorber Available?

    Yes, Customized Vibration Absorber is available. Size, Overall length, packing, marking etc, are all available. Besides, Vibration Absorber with bending, elbow, flare nuts and nipples are also available. Our Vibration Absorber can be used for Air conditioning, refrigeration system, marine and offshore, railway, truck etc.